Click here to make tpub.com your Home Page

Page Title: Table 9-5. Current, Speed, and Voltage Accepted Values
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2835-255-34
STARTER MOTOR TEST (Sheet 3 of 5)
8. CHECK RESISTANCE BETWEEN
SOLENOID TERMINALS 1 (1), 2 (2), AND 3
(3), AND BETWEEN TERMINALS (1, 2, 3)
AND SOLENOID HOUSING (4) WITH
MULTIMETER SET ON RX10,000 OHMS.
IF MULTIMETER READS ANYTHING BUT
INFINITY, REPLACE SOLENOID SWITCH
ASSEMBLY (PAGE 9-48).
CAUTION
Motor should not be run for more than 15 seconds
and should be cooled for 2 minutes after each run.
Motor could be damaged if run longer than 15
seconds.
9. CHECK MOTOR CURRENT, SPEED, AND
VOLTAGE (TABLE 9-5) AND (TM 9-4910-
485-12).
Table 9-5. Current, Speed, and Voltage Accepted Values
Accepted Values
Measurement
Current
60 to 90 Amps
7000 to 8500 RPM
Speed
18 to 20 V dc (specific gravity 1.25 minimum)
Voltage
Go on to Sheet 4
9-45

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business