TM 9-2835-255-34
STARTER MOTOR TEST (Sheet 3 of 5)
8. CHECK RESISTANCE BETWEEN
SOLENOID TERMINALS 1 (1), 2 (2), AND 3
(3), AND BETWEEN TERMINALS (1, 2, 3)
AND SOLENOID HOUSING (4) WITH
MULTIMETER SET ON RX10,000 OHMS.
IF MULTIMETER READS ANYTHING BUT
INFINITY, REPLACE SOLENOID SWITCH
ASSEMBLY (PAGE 9-48).
CAUTION
Motor should not be run for more than 15 seconds
and should be cooled for 2 minutes after each run.
Motor could be damaged if run longer than 15
seconds.
9. CHECK MOTOR CURRENT, SPEED, AND
VOLTAGE (TABLE 9-5) AND (TM 9-4910-
485-12).
Table 9-5. Current, Speed, and Voltage Accepted Values
Accepted Values
Measurement
Current
60 to 90 Amps
7000 to 8500 RPM
Speed
18 to 20 V dc (specific gravity 1.25 minimum)
Voltage
Go on to Sheet 4