Figure
4-32.
Disconnecting
or
connecting
turbosupercharger
at
mounting
base.
Disconnect and remove
1. Remove eight self-locking nuts (A), flat washers, and
cap screws attaching exhaust pipes to turbine housing.
2 . Separate exhaust pipes from turbine housing and
remove and discard two gaskets (B).
assembly
(C) from
3 . R e m o t e turbosupercharger
mounting base.
Connect and install
assembly ( C ) o n
1.
Position
turbosupercharger
mounting base.
2. Position new gaskets (B) between exhaust pipes and
turbine housing.
3. Install eight cap screws, flat washers, and self-locking
nuts (A) securing exhaust pipes to housing.
4-33.
Disconnecting
or
connecting
exhaust pipes at turbine housing and
removing
or
installing
turbosupercharger.