TM 9-2920-257-30&P
Table 2-1.
Generator Troubleshooting - Continued
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
Open Positive Rectifier Test.
Figure 2-3.
C h e c k f o r o p e n p o s i t i v e r e c t i f i e r s . Connect
Step 5.
ohmmeter to each of the three positive rectifier
leads in accordance with figure 2-3.
I f the ohmmeter reading is more than 100 ohms,
replace drive end housing assembly in
a c c o r d a n c e with paragraph 3-3, and go to step 8.
2-5
|