TM 9-2835-255-34
GAS TURBINE POWER UNIT REPLACEMENT (Sheet 21 of 30)
CAUTION
Use caution to prevent damage to turbine
rotor (5), mechanical guard (6) or regener-
ator assembly (1). Use extreme care not
to damage inside of regenerator assembly
while installing gas turbine power unit (2).
Avoid excessive upward or downward
movement of power unit (2) to prevent
damage to inside of regenerator assem-
bly. If damage occurs, replace regenera-
tor (1) with a serviceable assembly.
m . Using hoist and lifting sling (3), guide gas tur-
bine power unit (2) into position in regenerator
assembly (1). Apply only enough downward
pressure on lifting sling handle (4), in com-
bination with hoist, to position and guide pow-
er unit (2) into regenerator assembly (1).
Align gas turbine power unit rear assembly 15
n.
slots (7) with 15 spring pins (8) on mounting
flange (9).