TM 9-2835-255-34
GAS TURBINE POWER UNIT REPLACEMENT (Sheet 20 of 39)
NOTE
Mechanical guard (1) and gas turbine
power unit (2) should be kept together as
a matched set whenever removed from
regenerator assembly (3). Used service-
able units may be substituted, however.
Whenever possible, keep mechanical
guard (1) with, and positioned on, gas
turbine power unit (2) as removed.
Inspect mechanical guard (1) for warpage,
j
bends or deformation. Replace as required
with a used serviceable unit.
k.
Inspect 15 spring pins (4) in mounting flange
(5) of regenerator (6). Check for bent, misa-
ligned or missing spring pins (4). Replace re-
generator (6) if any of these conditions exist.
I.
Install mechanical guard (1) on rear of gas tur-
bine power unit (2) using alignment marks (7)
made during disassembly.
Go on to Sheet 21
6-81
Change 6
|