TM 9-2835-255-34
GAS TURBINE POWER UNIT REPLACEMENT (Sheet 8 of 30)
14. REMOVE THERMOCOUPLE WIRING HAR-
NESSES (1, 2, 3).
a.
Cut safety wire and remove 12 bolts (4) and
12 cable hangers (5).
b.
Remove 12 probes (6) from gas turbine power
unit (7).
NOTE
Wiring harnesses (1, 2, 3) do not have to be
removed from forward header of rear
module sub-assembly (8).
15. INSPECT WIRING HARNESSES (1, 2, 3) FOR
FRAYING OR WORN OUTER SHEATH AND BURNED
OR BROKEN PROBES (6). REPLACE AS REQUIRED
16. CAREFULLY BEND WIRING HARNESSES (1, 2, 3)
BACK AND INSERT PROBES (6) INTO GAS TURBINE
POWER UNIT THERMOCOUPLE PROBE BOSSES
(8).
Go on to Sheet 90
6-69
Change 6
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |