NO. 1 BEARING SEAL/PACKING RETAINER REPLACEMENT (Sheet 11 of 21)
2.  POSITION INLET HOUSING (1) NOSE DOWN ON
WORK SURFACE AND INSTALL FOUR BOLTS (2).
a.
Apply antiseize compound to four bolts (2).
Install and torque bolts (2) evenly between
40-45 lb-in (0.45-0.51 Nm).
Safety wire must be routed around outside
of spring pin (3) to prevent contact with
rotor.
b.
Using double twist method, install new safety
wire to two bolts (2) at 8 o'clock and 10
o'clock positions. install new safety wire to two
bolts (2) at 2 o'clock and 4 o'clock positions.
Run safety wire around outside of interceding
spring pin (3).
3.  APPLY SHORTENING COMPOUND TO NEW
PREFORMED PACKING (4) AND INSTALL INTO
GROOVE (5) AT REAR OF INLET HOUSING (1).