NO. 1 BEARING SEAL/PACKING RETAINER REPLACEMENT (Sheet 12 of 21)
4. INSTALL INLET HOUSING (1) ONTO LOW
PRESSURE ROTOR AND HOUSING ASSEMBLY (2).
Inlet housing (2) is heavy and may require
two persons to lift. Damage to compo-
nents or injury to personnel may result if
dropped or mishandled. Use firm grip
while lifting.
CAUTION
Use care not to bump low pressure com-
pressor rotor shaft (3) during installation.
Damage to shaft may result.
a.
Firmly grasp inlet housing (1) with both hands
and align IGV bellcrank and fork assembly (4)
on low pressure rotor and housing assembly
(2) with ball (5) attached to unison ring (6).
Go on to Sheet 13