3-2. TROUBLESHOOTING - CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
A. Remove bleed actuator
assembly and IGV
actuator  link  (TM  20-1).
B.  Inspect  IGV  actuator
lever  (1)  and  bearing
(2)  for  cracks,
corrosion  or  wear.
Replace  faulty  parts.
C.  Inspect  bracket  (3)  for
bends,  corrosion  or  worn
holes.  Replace  bracket
if  faulty.
D.  Inspect  two  pins  (4)  for
wear.  Replace  pins  (4)
if  faulty.
E.  Install  bleed  actuator
lever assembly and IGV
actuator  link  (TM  20-1).
F.  Verify  problem  is
solved.
9
A.
Remove  low  pressure
compressor housing assembly
(top  half)  (page  5-6).
B.  Remove  bellcrank,  link  and
control  (5)  from  lower
housing  (6).
C.  Check  to  see  if  bushing  (7)
turns  smoothly  on  inlet
guide  control  (8).
Does
bushing
bind
on
control?
CONTINUED ON NEXT PAGE
3-217