TM
9-2835-255-34
3-2. TROUBLESHOOTING - CONTINUED
I
I
( 2 ) E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED.
A.
Replace IGV actuator
cylinder (TM 20-1).
B. Verify problem is
solved.
I
8
A.
Unhook spring (1) from link
(2).
B. Remove bolt (3), washer (4),
spacer (5) and self-locking
nut (6) from link (2) and
lever (7).
C. Move lever (7) forward and
rearward, and feel for
binding.
Does IGV actuator lever move back
and forth without binding?
CONTINUED ON NEXT PAGE
Change 5
3-216
|