TM
9-2835-255-34
-
3-2. TROUBLESHOOTING CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
CONTINUED FROM STEP 6
A.
Line up hole (1) in
feedback control (2)
with hole (3) in
actuator lever f4). Put
quick-release pm (5) in
feedback control (2) and
actuator lever (4).
B. Line up hole (6) in
actuator lever (4) with
slot in rod (7). Put pin
(8) in actuator lever
(4) and rod (7).
C. Put washer (9) on pin
(8), and put new cotter
pin (10) In pin (8).
7.
Remove cotter pin (11),
washer (12), and pm (13).
B. Swing bracket (14) up and
away from connector rod end
(15).
C. M o v e I G V a c t u a t o r l e v e r ( 4 )
forward and rearward and
feel for binding.
Does IGV actuator lever move back
and forth without binding?
CONTINUED ON NEXT PAGE