3-2. TROUBLESHOOTING - CONTINUED
I
g. INLET GUIDE VANE (IGV)
(2) ES-26. IGV SYSTEM BINDS WHEN IGV
S Y S T E M - CONTINUED
ACTUATOR LEVER IS MOVED BY HAND.
-
CONTINUED.
CONTINUED FROM STEP 1
2
. A.
R e m o v e q u i c k - r e l e a se p i n ( 1 )
from lever (2) and feedback
control (3).
B . C h e c k q u i c k - r e l e a se p i n ( 1 )
for damage or wear. Replace
damaged or worn pin (1).
C. Check for binding of IGV
system by moving IGV
actuator lever (2) forward
and rearward.
Does IGV actuator
lever move
back
and forth without
binding?
Go to step 4.
A.
Line up hole (4) in
feedback control (3)
with hole (5) in
actuator lever (2). Put
q u i c k - r e l e a se p i n ( 1 ) i n
feedback control (3) and
actuator lever (2).
B. Line up hole (6) in
actuator lever (2) with
slot in rod (7). Put pin
(8) in actuator lever
(2) and rod (7).
C.
Put washer (9) on pin
(8), and put new cotter
pin (10) in pin (8).
CONTINUED ON NEXT PAGE
3-210
Change 5
|