3-2. TROUBLESHOOTING CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
SYSTEM - CONTINUED
- CONTINUED
CONTINU ED FROM STEP 2
A. Remove quick-release pin
3
(1) from feedback control
(2) and lever (3) on
EMFS (4).
B. Check quick-release pin (1)
for damage or wear. Replace
pin (1) If damaged or worn.
c . Check to see if feedback
control (2) moves freely up
and down when actuator level
(5) is moved forward and
rearward.
Does
feedback
control
move
freely?
A. Replace IGV feedback
control assembly
(TM 20-1).
B. Verify problem is
solved.
CONTINUED ON NEXT PAGE