3-2. TROUBLESHOOTING - CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
Supplies:
Tools:
Cotter  pin
(Item
5,  Appendix  E)
General  mechanic's  tool  kit:
Cotter  pin
(Item
11,  Appendix  E)
automotive  (SC  5180-90-N26)
Cotter  pin
(Item
114,  Appendix  E)
Punch  (Item  102,  Appendix  D)
Spring  pin
(Item
113,  Appendix  E)
Wiping  rag
(Item
14,  Appendix  B)
References:
TM 20-1
1
A.
Remove  cotter  pin  (1)  from
pin  (2).
B. Remove washer (3) and pin
(2).
C.  Move  air  bleed  valve  rod  (4)
forward  and  rearward  while
feeling  for  binding.
Does air bleed valve rod move back
and  forth  without  binding?
A.
Replace  air  bleed
butterfly  valve
(TM 20-1).
B.  Verify  problem  is
solved.
CONTINUED ON NEXT PAGE
3-209