TM
9-2835-255-34
3-2. TROUBLESHOOTING - CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
Supplies:
Tools:
Cotter pin
(Item
5, Appendix E)
General mechanic's tool kit:
Cotter pin
(Item
11, Appendix E)
automotive (SC 5180-90-N26)
Cotter pin
(Item
114, Appendix E)
Punch (Item 102, Appendix D)
Spring pin
(Item
113, Appendix E)
Wiping rag
(Item
14, Appendix B)
References:
TM 20-1
1
A.
Remove cotter pin (1) from
pin (2).
B. Remove washer (3) and pin
(2).
C. Move air bleed valve rod (4)
forward and rearward while
feeling for binding.
Does air bleed valve rod move back
and forth without binding?
A.
Replace air bleed
butterfly valve
(TM 20-1).
B. Verify problem is
solved.
CONTINUED ON NEXT PAGE