TM 9-2520-270-34
11. CHECK HOUSING (1).
9. CLEAN COOLANT AND TIME DELAY
VALVE ASSEMBLY.
a.
Using micrometer caliper set and
telescoping gage set, measure four
a. Clean assembly and hardware. See
diameters (2).
Replace housing (1) if any measure-
b.
10. INSPECT COOLANT AND TIME DELAY
ment is greater than 1.165 inches
VALVE ASSEMBLY.
(29.59 mm).
a. Inspect assembly, piece parts, and
c.
Using micrometer caliper set and
inserts. See page 2-5.
telescoping gage set, measure
diameter (3).
b. Repair inserts if damaged. See task
R E P A I R COOLANT AND TIME DELAY
d.
Replace housing (1) if measurement is
VALVE HOUSING INSERTS, page 4-415.
greater than 0.814 inch (20.68 mm).
13. CHECK DIRECTIONAL CONTROL
SLIDE (5).
12. CHECK SPRING (4).
a. Using micrometer caliper set,
measure two diameters (6).
a.
Using indicator caliper, measure free
b. Replace slide (5) if either measure-
length of spring (4). Replace spring
ment is less than 0,8112 inch
if free length is less than 3.32 inches
(20.604 mm).
(84.3 mm).