TM 9-2520-270-34
51. REPAIRER AND HELPER, TURN
HOUSING (1) OVER.
53. IF BEARING (3) WAS REMOVED,
CHECK BORE (4).
52. CHECK MECHANICAL HOUSING (2).
a. Using telescoping gage set and
a. Using micrometer caliper set,
micrometer caliper set, measure
measure outside diameter of
inside diameter of bore (4).
mechanical housing (2).
b. If measurement is greater than
b . If measurement is less than
5.9070 inches (150.038 mm), go to
3.1478 inches (79.954 mm), go to
step 55. If not, go to step 54.
step 55. If not, go to step 53.
55. R E P L A C E LEFT-HAND INTERMEDIATE
HOUSING. RECORD FAILURE ON
DA FORM 2407 AND RETURN
DEFECTIVE HOUSING TO DEPOT.
GO TO STEP 58.
56. C L E A N LEFT-HAND iNTERMEDIATE
HOUSING.
a. Clean housing and piece parts.
57. INSPECT LEFT-HAND INTERMEDIATE
HOUSING.
54. CHECK BEARING BORE (5).
a. Inspect housing, piece parts
a. Using telescoping gage set and
and inserts. See page 2-5.
micrometer caliper set, measure
b. Repair inserts if damaged. See
inside diameter of bore (5).
task REPAIR LEFT-HAND
b. If measurement is greater than
i N T E R M E D I A T E MECHANICAL
4.5290 inches (115.037 mm), go to
HOUSING INSERTS, page 4-253.
step 55. If not, go to step 56.
GO TO NEXT PAGE
4-247
Change 2