47. INSPECT WIRE FABRIC (1).
48. CHECK OUTPUT BEARING
a.
Inspect fabric (1) for dirt. If fabric
SUPPORT (3).
is plugged, clean it. See page 2-2.
a. Using micrometer caliper set,
b.
Inspect fabric (1) for loose or bent
measure outside diameter of bearing
wires.
support (3).
c.
If fabric (1) is damaged, housing (2)
b. If measurement is less than
must be replaced. Go to step 55. If
3.3443 inches (84.945 mm), go to
fabric is not damaged, go to step 48.
step 55. if not, go to step 49.
50. CHECK MECHANICAL HOUSING (5).
a. Using micrometer caliper set,
measure two outside diameters (6)
and one outside diameter (7) on
49. CHECK MECHANICAL HOUSING (4).
mechanical housing (5).
a. Using micrometer caliper set,
b. If either measurement (6) is less
measure outside diameter of
than 2.9990 inches (76.175 mm), go to
mechanical housing (4).
step 55. If not, go to step 50c.
b. If measurement is less than
c. If measurement (7) is less than
4.3288 inches (109.952 mm), go
3.3445 inches (84.950 mm), go to
to step 55. If not, go to step 50.
step 55. If not, go to step 51.
4-246
|