TM 746-10
d. Carbon-dioxide compressor.
Do not apply
Do not apply preservatives to the refrigerant system,
preservatives to interior surfaces. Seal openings with
piping, or valves. Attach a tag to the electrical power
tape.
connection or the starting system bearing the
e. Dry ice press. Actuate the dry ice press to
information:
"OPEN VALVE BEFORE THE
ensure coating of all interior surfaces of pumps, piping,
EQUIPMENT IS OPERATED."
and valves. Coat pressure platens with P-10 and cover
f. Water system. Completely drain the water
with greaseproof barrier material. Secure with tape.
system, including the pump, and dry with dry
Secure control levers to prevent movement.
compressed air. Preserve pump per paragraph 4-4.
f. Scales. Lock, block, and cushion to prevent
Leave drains open.
damage by vibration. Coat machined surfaces with P-
g. Testing apparatus. Unit pack each item in a
10 and cover with greaseproof barrier material. Cushion
fiberboard box.
the scales with cellulosic cushioning.
h. Valves
(oxygen-nitrogen
generating
and
g. Hoses and power cables. Secure in storage
charging plant). Close valves throughout the plant.
area provided.
EXCEPTION Open the four condensate-trap drain
h. Bandsaw. Coat machined surfaces with P-10.
valves on the air compressor.
i. Semitrailer. Preserve per applicable paragraphs
i. Compressor air intake and liquid oxygen outlet
of this chapter.
4-30. Firefighting Equipment
plant). Cushion components within their cabinets with
cellulosic cushioning.
a. Electric motor sirens, battery chargers, and
j. Power cables and hoses. Place and secure in
monitor-type nozzles. Seal openings with tape.
storage area provided.
b. Water and foam tanks. Drain the tanks and all
k. Scales. Lock, block, and cushion to prevent
connecting piping. Leave drain valves open.
damage and then place and secure in the storage
c. Fire extinguisher charges. Pack in fiberboard
compartment using the securing device provided.
boxes and waterproof seal with tape.
l. Semitrailer. Preserve per applicable paragraphs
d. Floodlights, lanterns, and flashlights. Pack in
of this chapter.
fiberboard boxes. Cushion items within the box with
CAUTION
cellulosic cushioning.
e. Water and carbon-dioxide fire extinguishers.
No preservative will be applied to surfaces that
Pack in fiberboard boxes.
will come in contact with liquid or gaseous
f. Gaskets, expansion rings, and fittings. Unit
form of oxygen or nitrogen. No preservative
pack submethod IC-1.
will be applied to surfaces that are subject to
extremely, low temperature. No preservative
g. Hoses and rope. Coil and secure with twine.
will be applied to high-pressure systems, lines,
Cover ends of hoses with greaseproof barrier material
hoses, pipes, etc., including relief valves.
and secure with tape.
h. System vehicle. Clean, dry, and preserve power
4-29. Conversion Unit, Carbon-dioxide, Semitrailer-
train, brakes, steering, and all other components of the
mounted
mobility aspects of the vehicle per applicable
Clean and dry per paragraphs 3-3 and 3-4 and as
paragraphs of this chapter. Place components in truck
specified in MIL-C-52211.
compartments or tool boxes, if space permits, or pack in
a. Vent openings. Seal vent openings on trailer
plywood, wood, or triple wall fiberboard boxes. Secure
roof with waterproof barrier and secure with tape.
boxes and ladders inside of truck with metallic strapping.
Pack in a closed crate those component items that
b. Heater. Drain heater fuel tank and fog interior
cannot be accommodated within the truck.
with P-10. Reinstall the drain plug.
4-31. Diving Equipment Sets
c. Carbon-dioxide and refrigeration system. Drain
the refrigerant and carbon-dioxide system. Dry interior
a. Gaskets, gloves, glove inserts, filter elements,
surfaces of the system with dry compressed air. Close
cloth, cotton cord, cuffs, filters, socks, strap, rubber
valves and seal openings into the system with tape.
tubing, diver's knife, drawers, and undershirts.
Individually unit pack each item submethod IC-1.
b. Adapters, bags, clamps, harness, helmet
cushion, machine screws, reducers, wing nuts, nipples,
packing material, safety latch, and beeswax. Unit pack
submethod IC-1.
4-6
|