TM 55-4920-411-13&P
NOTE
Use table 4-4 when troubleshooting Signal
Generator Display Boards in conjunction
with this table as applicable. (Also, see
PROBABLE CAUSE
REMEDY
.--..-- --
Open fuse, FUl
Power lamp fails to light when power switch is on.
Replace
(Para 4-8)
Replace
Defective POWER switch, S1
Replace
Defective power lamp, DS1
Repair or
Defective power cable
replace
Defective display/s, DS1, DS2
Replace
SECONDS display does not read 00 when power is
applied to signal unit.
Replace
C4, R9, Z1-Z5, or Z9 on display
board
+ 12 vdc or + 5 vdc supply on
Repair
signal generator board T1 or
(Fig 4-7 and
associated components
FO-1)
Replace
START/STOP/RESET
SECONDS display reads 00 when power is applied
switch, S5
to signal unit but does not proceed to display
seconds when START/STOP/RESET switch is
Replace
R7 on display board
pressed.
Replace
Z6-Z9 on display board
I
Repair
1 MHZ oscillator circuit on
signal generator board
Replace
Z9 on display board
SECONDS display starts running when power is
applied to signal unit and cannot be reset
Para 4-8)
4-4
|