Section III. MAINTENANCE
INTRODUCTION.  This section contains procedures for maintaining the test
set.  It includes instructions for performing cleaning, troubleshooting, repair,
disassembly, reassembly, adjustments, and test procedures.
CLEANING .
Periodically clean the test set using procedures given below.
a.
Case, Cover and Panel Assembly.
Proceed as follows:
(1) Wipe case, cover, and panel assembly with lint-free cloth dampened
with soap and water.
(2) Rinse thoroughly with fresh, clean water.
WARNING
When using compressed air, do not exceed 10 psi.  Compressed
air in excess of 10 psi can cause injury.  Do not direct
compressed air against skin.
Electrical Parts.
Clean with soft-bristle brush or with compressed air
(ohserve WARNING).
TROUBLESHOOTING .  Troubleshooting procedures should be accomplished in
the following order.  First perform a pre-troubleshooting check, then a visual
check, then a resistance (continuity) check and finally if the trouble has not
yet been located, troubleshoot by consulting the troubleshooting guide.
a.
Pre-Troubleshooting Check.
Proceed as follows:
(1) Check that BAT LEADS are properly connected to the battery; +12 V
lead to positive terminal and -12 V lead to negative terminal.
(2) Check that the PUSH TO RESET window is clear. If it is red, depress
the PUSH TO RESET switch to reset the circuit breaker.
(3) Check that battery or power supply voltage being used is at least
12 volts and does not exceed 16 volts.
b.
Visual Check.  Remove 12 front panel screws and lift out the front
panel printed circuit board assembly.  Visually inspect for open wire,
discolored resistor, signs of burnt component, and any other visible
signs of malfunction.
C.
Resistance Check. Refer to table 3-1 for resistance check. Disconnect
the battery from the unit and perform the resistance (continuity) checks
with the switches as indicated in table 3-1.