TM 9-4910-736-14&P
WARNING
When PUSH TO TEST switch is depressed HIGH VOLTAGE is
present across all leads and coil under test. DO NOT
touch leads or coil under test when PUSH TO TEST switch
is depressed.
(6) Observe WARNING and depress PUSH TO TEST switch. While holding PUSH
TO TEST switch depressed, adjust COIL CURRENT control clockwise
until meter indicates 20 to 25 KV on the black scale. Check that
COIL FLASHOVER indicator does not illuminate.
(7) Release PUSH TO TEST switch.
(8) Set COIL CURRENT control to extreme counterclockwise position.
(9) Set FUNCTION switch to OFF.
2-13/(2-14 blank)
|