![]() TM 9-2910-226-34 
(D). Insert a feeler gage (E) to obtain a clearance of 
0.002 to 0.004-inch between the operating lever and 
operating shaft bearing; move lever as necessary to 
obtain this clearance, Torque tighten nut (C) to 70- 
75 inch-pounds. Install dust cover, lockwasher and 
machine bolt; refer to ((17) above). Check operating 
lever clearance at dust cover ((18) above). 
Figure 3-86. Identification of oil baffles. 
Figure 3-85. Installing operating lever using a feeler gage 
(code A pumps). 