TM 9-2910-226-34
(D). Insert a feeler gage (E) to obtain a clearance of
0.002 to 0.004-inch between the operating lever and
operating shaft bearing; move lever as necessary to
obtain this clearance, Torque tighten nut (C) to 70-
75 inch-pounds. Install dust cover, lockwasher and
machine bolt; refer to ((17) above). Check operating
lever clearance at dust cover ((18) above).
Figure 3-86. Identification of oil baffles.
Figure 3-85. Installing operating lever using a feeler gage
(code A pumps).