Page Title: TEST ARMATURE
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2835-255-34
STARTER MOTOR REPAIR (Sheet 5 of 11)
4. TEST ARMATURE (1) FOR SHORT
CIRCUITS.
NOTE
Short circuit in armature (1) will pull hacksaw
blade against armature core (2) and cause blade to
vibrate.
a. With growler (3) turned on, hold blade
about 1/32-inch (0.794 mm) away from
armature (1).
b. Turn armature (1) slowly. If blade is
pulled against core (2), assemble starter
motor (page 9-59) and replace.
5. INSPECT ARMATURE SHAFT SPLINES (4)
FOR DAMAGE, IF DAMAGED, ASSEMBLE
STARTER MOTOR (PAGE 9-59) AND
REPLACE.
6. INSPECT CONTACT SURFACE (5) FOR
ROUGH SURFACE, PITS, BURNS, OR
HARD CARBON OR OIL COAT, IF
DAMAGED, DO STEPS 7, 8, AND 9.
Go on to Sheet 6
9-55