ACCESSORY GEARBOX CLEANING AND REPAIR (Sheet 30 of 40)
4.  IF GAP (1) IS NOT WITHIN 0.1 30-0.150 INCH
(3.30-3.81 MM), REMOVE NOZZLE (2) AND TUBE
ASSEMBLY (3) AND ADJUST (REPLACE) WASHER
(4) TO CORRECT GAP (1).
a.
Remove nozzle (2) and seal washer (5).
b.
Remove tube assembly (3) and washer (4).
Replace or add washer (4) as needed to cor-
rect gap (1).
5.  IF REMOVED, INSTALL TUBE ASSEMBLY (3)
AND NOZZLE (2). TORQUE NOZZLE (2) BETWEEN
145-160 LB-IN (16-18 Nlm).
a.
Place tube assembly (3) with clamp (6)
installed and washer (4) in housing (7).
b.
Install nozzle (2) and new seal washer (5) into
tube assembly (3). Torque nozzle (2) be-
tween 145-160 lb-in (16-18 Nlm). Lock-
wire nozzle (2).
6.  SECURE CLAMP (6) TO HOUSING (7) WITH
SCREW (8).