TM 9-2835-255-34
DIRECT LINEAR VALVE REPLACEMENT (Sheet 5 of 6)
.5.
POSITION CONNECTOR (1), WITH SLOT
(2) IN TWELVE O'CLOCK POSITION, ON
FLANGE CONNECTOR ELBOW (3).
INSTALL FOUR NEW BOLTS (4).
TIGHTEN BOLTS IN STAGGERED
SEQUENCE.
6.
SECURE DIRECT LINEAR VALVE (5)
WITH THREE WASHERS (6) AND THREE
NEW SCREWS (7). TORQUE IN 5 LB-.lN
INCREMENTS TO 15-20 LB-IN (1 .69-2.26
N.m ).
INSTALL ACCESS COVER (8) AND NEW
7.
GASKET (9). SIX NEW SCREWS ( 10,1l)
AND) SIX WASHERS (12). TORQUE
SCREWS IN STAGGERED SEQUENCE
BETWEEN 25-30 LB-lN (2.82-3:39 N m).
K.
ATTACH BRACKET (13) TO LINEAR
VALVE (5) WITH SCREW (14) AND
TORQUE TO 40-45 LB-IN (4.52-5.08 N .111).
a.
Remove screw (14) and swing bracket (13)
back in posit ion.
b.
Attach bracket (13) to linear valve (5) with
(4.52-5.08 N.m).
c.
Tighten screw securing bracket (13) to
clamps (15).
dl.
Lockwire two screws (14) on top of linear
valve.
Go on to Sheet 6
7-44 Change 4
|