TM 9-2835-255-34
GAS TURBINE POWER UNIT REPLACEMENT (Sheet 15 of 30)
CAUTION
Use caution to prevent damage to turbine
rotor (5), mechanical guard (6) or regener-
ator assembly (1). Use extreme care not to
damage inside of regenerator assembly
(1) while installing gas turbine power unit
(2). Avoid excessive upward or downward
movement of power unit (2) to prevent
damage to inside of regenerator assembly
(1). If damage occurs, replace regenerator
with a serviceable assembly.
3. USING HOIST AND LIFTING SLING (3), GUIDE
GAS TURBINE POWER UNIT (2) INTO POSITION IN
REGENERATOR ASSEMBLY (1).
a.
Carefully install gas turbine power unit (2) into
regenerator assembly (1) by applying only
enough downward pressure on lifting sling
handle (4), in combination with hoist, to posi-
tion and guide power unit (2) into regenerator
assembly (1).
b.
Align gas turbine power unit rear assembly 15
slots (7) with 15 spring pins (8) on mounting
flange (9).
Go on to Sheet 16
6-76