TM 9-2835-255-34
GAS TURBINE POWER UNIT REPLACEMENT (Sheet 12 of 30)
NOTE
Mechanical guard (1) and gas turbine
power unit (2) should be kept together as
a matched set whenever removed from
regenerator assembly (3). Used service-
able units may be substituted, however.
Whenever possible, keep guard (1) with,
and positioned on, power unit (2) as re-
moved.
28. REMOVE MECHANICAL GUARD (1) FROM
REGENERATOR ASSEMBLY (3).
29. ALIGN TABS (4) ON MECHANICAL GUARD (1)
WITH GROOVES (5) IN GAS TURBINE POWER UNIT
ASSEMBLY OUTER SHROUD (6) IN SAME POSITION
AS BEFORE REMOVAL.
30. USING MARKER, MAKE MATCH MARKS (7) ON
MECHANICAL GUARD (1) AND OUTER SHROUD (6).
REMOVE MECHANICAL GUARD (1) AND SET ASIDE.
31. PLACE GAS TURBINE POWER UNIT (2) ON
CLEAN, DRY WORK SURFACE AND REMOVE HOIST
AND LIFTING SLING (8). COVER GAS TURBINE
POWER UNIT (2) WITH A PLASTIC GARBAGE BAG.
32. INSTALL SEVEN BOLTS (9) IN THREADED
HOLES (10) OF LIFTING SLING (8). SET LIFTING
SLING (8) ASIDE FOR LATER USE.
Go on to Sheet 13