NO. 2 AND 3 BEARING SEAL/PACKING RETAINER REPLACEMENT (INCLUDING INTERSHAFT SEAL)
(Sheet 45 of 49)
30. SECURE LOW PRESSURE COMPRESSOR
HOUSING (1) TO INTERMEDIATE HOUSING (2)
WITH 28 BOLTS (3). TIGHTEN BOLTS (3) USING
TORQUEMETER WITH CROWSFOOT (TB 43-0218).
(NORMAL TORQUE VALUE, NOT CORRECTED FOR
CROWSFOOT, IS BETWEEN 88-75 LB-IN
(7.88-8.47 NM) TORQUE.)
a.
Apply antiseize compound to 28 bolts (3).
b. Secure low pressure compressor housing (1)
to intermediate housing (2) with 28 bolts (3)
and 28 new lockwashers (4).
c.
Tighten bolts (3) using torque adapter with
crowsfoot (TB 43-0218). (Normal torque val-
ue, not corrected for crowsfoot, is between
68-75 lb-in (7.68-8.47 N.m) torque.)
d.
Remove lifting sling (5).
31. TIGHTEN LOWER TWO BOLTS (6), ON EACH
SIDE OF LOW PRESSURE COMPRESSOR HOUSING
(1) SPLIT LINE, BETWEEN 70-95 LB-IN
(7.90-10.73 N.M) TORQUE.
32. INSTALL TWO NEW GASKETS (7) AND MOUNT-
ING PLATES (8) AT TWO PLACES ON INTERMEDI-
ATE HOUSING (2) USING FOUR BOLTS (9).
TIGHTEN BOLTS (9) TO 45 LB-IN (5.08 N.M)
TORQUE.
LE5591
Go on to Sheet 46