TM 9-2835-255-34
NO. 2 AND 3 BEARING SEAL/PACKING RETAINER REPLACEMENT (INCLUDING INTERSHAFT SEAL)
(Sheet 39 of 49)
d.
Using depth gage micrometer, check distance
(A) from forward end (1) of No. 2 bearing seal
housing (2) to top face of packing retainer (3)
at two places 180 degrees apart. Dimension
(A), measured at both places, shall be
within 0.002 inch (0.0508 mm) of each other.
21. INSTALL RETAINING RING (4) IN NO. 2 BEARING
HOUSING (2).
22. LUBRICATE NEW PREFORMED PACKINGS (5,6)
WITH SHORTENING COMPOUND AND INSTALL
ONTO NO. 2 BEARING HOUSING (2).
CAUTION
Use extreme caution during installation of
No. 2 bearing housing (2) not to damage
packing retainer (3).
23. INSTALL NO. 2 BEARING HOUSING (2) ONTO
LOW PRESSURE COMPRESSOR ROTOR SHAFT (7)
USING PUSHER SLEEVE (8).
a.
Lubricate low pressure compressor rotor shaft
(7) with lubricating oil.
b.
Install No. 2 bearing housing (2), with seal end
facing down, onto aft end of low pressure
compressor rotor shaft (7).
c.
Install pusher sleeve (8) against inner bearing
race in No. 2 bearing housing (2) and tap
sleeve (8) until No. 2 bearing housing (2) is
seated.
Go on to Sheet 40