TM 9-2835-255-34
NO. 2 AND 3 BEARING SEAL/PACKING RETAINER REPLACEMENT (INCLUDING INTERSHAFT SEAL)
(Sheet 8 of 49)
c.
Remove jacking screws (1), bearing housing
(2) and ring spacer (3) from inlet housing (4).
Retain ring spacer (3) for further use.
d.
Remove and discard two preformed packings
(5) from bearing housing (2).
4. INSTALL LOCKING CUP HOLDING FIXTURE (6)
ON INLET HOUSING (4).
NOTE
Locking cup holding fixture (6) has an
"offset hole" which will be at 7 o'clock
position when properly installed on inlet
housing (4).
a.
Place locking cup holding fixture (6) onto inlet
housing (4) and ensure tangs of holding fix-
ture (6) engage packing retainer (7).
b.
Secure fixture (6) to inlet housing (4) with six
bolts (8) removed in step 3.a.
LE5552
Go on to Sheet 7
5-80
Change 6
|