NO. 1 BEARING SEAL/PACKING RETAINER REPLACEMENT (Sheet 15 of 21)
NOTE
Layers of laminated ring spacer (1) can be
peeled away until desired thickness is
achieved. If too thin, replace with a new
ring spacer (1).
7.  TEMPORARILY INSTALL BEARING HOUSING (2)
ONTO SLEEVE BUSHING (3) TO CHECK FOR COR-
RECT GAP (4) UNDER BEARING OUTER RACE (5).
Install bearing housing (2) (without preformed
a.
packings) and predetermined ring spacer (1)
onto sleeve bushing.
Install three slave bolts (6), washers (7) and
b.
nuts (8) and tighten securely.
Using feeler gage, check for actual gap (4) of
c.
0.001-0.003 inch (0.025-0.076 mm) between
bearing race (5) and sleeve bushing (3) for a
full 360 degrees.
If actual gap (4) is not 0.001-0.003 inch
d.
(0.025-0.076 mm), recalculate ring spacer
size and repeat steps 7.a through 7.c.
8.  REMOVE BEARING HOUSING (2) RING SPACER
(1) AND BEARING RACE (5) FROM SLEEVE BUSH-
ING (3).
LE5514
Go on to Sheet 16