NO. 1 BEARING SEAL/PACKING RETAINER REPLACEMENT (Sheet 7 of 21)
e.
Remove four self-locking nuts (1) and four
cap screws (2).
f.
Ensure inlet guide vane (IGV) bellcrank (3) is
in full closed position.
NOTE
Inlet housing (4) is heavy and may require
two persons to lift. Damage to compo-
nents or injury to personnel may result if
dropped or mishandled. Use firm grip
while lifting.
CAUTION
Use care not to bump low pressure com-
pressor shaft (5) when removing inlet
housing (4). Damage to shaft may result.
g.
Firmly grasp inlet housing (4) with both hands .
and pull straight off low pressure rotor and
housing assembly (6). Place inlet housing
(4) nose down on clean work surface.
h.
Remove and discard preformed packing (7)
from inlet housing (4).