TM 9-2835-255-34
LOW PRESSURE ROTOR AND HOUSING ASSEMBLY (COMPRESSOR) AND HIGH PRESSURE
AXIAL (COMPRESSOR AND ROTOR CLEANING (Sheet 5 of 21)
INSTALL VANE ASSEMBLIES (1) IN CASE
7.
(2) IN SAME ORDER THEY WERE RE-
MOVED.
a. Apply small amount of beeswax on crown
(3) of each vane assembly (1) to hold vane
assemblies in place in case (2).
b. Aline hole in each vane assembly end (4)
with respective pin (5), and press vane
assemblies (1) in case (2).
REPEAT STEPS 3. THROUGH 7. AND
8.
CLEAN HIGH PRESSURE CASE AND
STATOR ASSEMBLY (TOP HALF) (6).
WARNING
PREPARE NEW BATCH OF CLEANING
9.
SOLUTION BY MIXING ONE PART OF
ALKALINE DESCALER COMPOUND TO
FOIIR PARTS OF FRESH HOT WATER.
WARNING
Be careful not to get fingers caught between
compressor blades (7) and inlet guide vanes (8).
Blades (7) ,are sharp and can cut you.
10. CLEAN INLET HOUSING (9) AND INLET
GUJDE VANES (8) WITH TOOTHBRUSH,
PREMJXED CLEANING SOLUTION AND
RAG.
a.
Clean inlet housing (9) with rag dipped in
premixed cleaning solution.
b.
Scrub inlet guide vanes (8) with brush and
premixed cleaning solution. Wipe with
clean rag.
Goon to Sheet 6