TM 9-2835-255-34
LOW PRESSURE ROTOR AND HOUSING ASSEMBLY (COMPRESSOR) AND HIGH PRESSURE
CAUTION
Oven cleaner contains solvents that may dissolve
nonmetallic materials. Do not allow oven cleaner to
contact abradable seal (1) at inner diameter of vane
assemblies (2).
CLEAN VANE ASSEMBLIES (2) WITH
5.
OVEN CLEANER, TOOTHBRUSH AND
PREMIXED CLEANING SOLUTION.
a. Spray vane assemblies (2) with oven
cleaner, being careful not to get any on the
abradable seal (1) at inner diameters. Let
cleaner work for 45 minutes.
b. Scrub vane assemblies (2) with toothbrush,
and rinse in premixed cleaning solution.
c. Rinse vane assemblies in fresh clean hot
tap water bath.
d. Check to see if vane assemblies (2) are
clean. Repeat steps a. through c. as needed.
WARNING
Compressed air used for cleaning purposes will not
exceed 30 PSI. Use only with effective chip
guarding and personal protective equipment
(goggles/faceshield, gloves, etc).
6.
CLEAN CASE (3) WITH TOOTHBRUSH
AND PREMIXED CLEANING SOLUTION.
a. Clean case (3) with toothbrush and pre-
mixed cleaning solvent.
b. Flush case (3) with hot tap water, and dry
using shop air.
Go on to Sheet 5
Change 4 5-37
|