TM 9-2835-255-34
INTERMEDIATE (LOW PRESSURE) HOUSING (TOP HALF) REPLACEMENT
(Sheet 5 of 6)
5. INSTALL BRACKET (1) AND LEVER (2).
a. Apply antiseize compound to bolt (3).
Aline bracket (1) and two spacers (4)
under flange (5), Loosely install bolt (3)
and new nut (6).
b. Apply antiseize compound to short bolt
(7). Aline hole in lever pin (8) with hole
in housing (9). Install bolt (7) and new
nut (10).
c. Apply antiseize compound to two bolts
(11). Install bolts (11) and new nuts (12).
d. Tighten bolt (3) and nut (6).
6. INSTALL ASSEMBLED CYLINDER (13)
AND BRACKET (14).
a. Apply antiseize compound to long bolt
(15) and short bolt (16). Position bracket
(14), cylinder (13), and two spacers (17) on
housing (9). Loosely install long bolt (15)
and new keywasher (18).
b. Loosely install short bolt (16) and new
nut (19). Tighten bolts (15, 16) and nut
(19). Bend tabs on keywasher (18).
c. Apply antiseize compound to two bolts
(20). Install bolts (20) and new
lockwashers (21).
Go on to Sheet 6