TM 9-2835-255-34
3-2. TROUBLESHOOTING - CONTINUED
(3)
ES-30. LOW PRESSURE COMPRESSOR
h. LOW PRESSURE COMPRESSOR -
RUBS OR BINDS WHEN TURNED BY
CONTINUED
HAND AND MORE THAN ONE HALF OF
THE ACCESSORY GEARBOX (AGB)
MAGNETIC PLUG IS COVERED WITH
METAL CHIPS. - CONTINUED
A.
Salvage Gas Turbine Power
Unit (page 6-63).
B.
Clean AGB (page 7-46).
C.
Replace oil pump
(TM 20-1).
D.
Replace engine oil cooler
(TM 20-1).
E.
Replace engine AC
generator (TM 20-1).
F.
Clean cooler and generator
lines (TM 20-1).
G.
Verify problem is solved.
CAUTION
Extreme care should be taken
when handling low pressure
turbine rotor shaft (1). Banging,
jarring or rough handling will
cause damage to No. 5 bearing
carbon seal.
A. Lift end (2) of shaft (1) slightly
to center shaft (1), then push
shaft (1) in to establish
clearance between power
turbine disc (3) and nozzle (4)
and to load No. 5 bearing (5).
B. Turn shaft (1), listen and feel
for rubbing or binding.
Does shaft turn smoothly with no
unusual noises?
CONTINUED ON NEXT PAGE