3-2. TROUBLESHOOTING - CONTINUED
g. INLET GUIDE VANE (IGV)
(3) ES-27. LEVER ON ELECTRO-
S Y S T E M - CONTINUED
u n m e c h a n i c a l FUEL SYSTEM (EMFS)
DOES NOT MOVE WHEN IGV ACTUATOR
LEVER IS MOVED.
This section contains troubleshooting to determine the reason the
feedback lever on the EMFS does not move when the IGV actuator lever
is
moved. The IGV actuator lever is connected to the EMFS feedback lever
through a feedback control (cable). The feedback control is connected to
both levers with quick-release pins. Missing or improperly installed
quick-release pins, a damaged or faulty feedback control, or a faulty
IGV power transformer on the EMFS could be the reason the EMFS lever
does not move when the IGV actuator lever is moved. The art on this page
provides an overview of the affected parts. Refer to this page along
with in-text art while performing troubleshooting.
3-220
Change 5
|