TM 9-2835-255-34
3-2. TROUBLESHOOTING - CONTINUED
E S - 2 6 . IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
CONTINUED FROM STEP 4
I
5
A.
Remove tube assembly (bottom
of IGV actuating cylinder)
(TM 20-1).
B. Remove tube assembly (top of
IGV actuating cylinder
(TM 20-1).
C. Check tube assemblies for
clogging.
Are
tube
assemblies
clogged?
Line up hole (1) in
A.
feedback control (2)
with hole (3) in
actuator lever (4). Put
quick-release pin (5) in
feedback control (2) and
actuator lever (4).
Line up hole (6) in
B.
actuator lever (4) with
slot in rod (7). Put pin
(8) in actuator lever
(4) and rod (7).
Put washer (9) on pin
C.
(8), and put new cotter
pin (10) In pin (8).
Replace EMFS (TM 20-1).
D.
Verify problem is
E.
solved.
CONTINUED ON NEXT PAGE
3-213
Change 5
|