3-2. TROUBLESHOOTING - CONTINUED
E S - 2 6 .  IGV SYSTEM BINDS WHEN IGV
g. INLET GUIDE VANE (IGV)
ACTUATOR LEVER IS MOVED BY HAND.
S Y S T E M - CONTINUED
- CONTINUED
CONTINUED FROM STEP 4
I
5
A.
Remove  tube  assembly  (bottom
of  IGV  actuating  cylinder)
(TM 20-1).
B. Remove tube assembly (top of
IGV  actuating  cylinder
(TM  20-1).
C.  Check  tube  assemblies  for
clogging.
Are
tube
assemblies
clogged?
Line  up  hole  (1)  in
A.
feedback  control  (2)
with  hole  (3)  in
actuator  lever  (4).  Put
quick-release  pin  (5)  in
feedback  control  (2)  and
actuator  lever  (4).
Line  up  hole  (6)  in
B.
actuator  lever  (4)  with
slot  in  rod  (7).  Put  pin
(8)  in  actuator  lever
(4)  and  rod  (7).
Put  washer  (9)  on  pin
C.
(8),  and  put  new  cotter
pin  (10)  In  pin  (8).
Replace  EMFS  (TM  20-1).
D.
Verify  problem  is
E.
solved.
CONTINUED ON NEXT PAGE
3-213
Change 5