3-2. TROUBLESHOOTING - CONTINUED
1
E S - 2 5 .  INLET GUIDE VANES (IGVS)
(1)
g. INLET GUIDE VANE (IGV)
DO NOT MOVE WHEN IGV BELLCRANK
S Y S T E M - CONTINUED
I S TURNED BY HAND. - CONTINUED
I
CONTINUED FROM STEP 2
Install  bellcrank,  link
A..
and  control  (1)  in  lower
housing  (2)  making  sure
that  fork  (3)  is
positioned around  ball
joint  on  IGV  unison
ring.
B.  I n s t a l l  t o p  h a l f  o f  l o w
pressure  compressor
housing  assembly  (page
5-8).
Install  bolt  (4),  washer
C.
(5),  spacer  (6)  and  new
self-locking  nut  (7)  in
link  (8)  and  lever  (9).
Hook  spring  (10)  on
link  (8).
D. V e r i f y  p r o b l e m  i s
solved.
END OF T A S K