Blower and Water Pump Drives Maintenance Instructions (Cont)
10-4. BLOWER DRIVE SEAL RING REMOVAL/INSTALLATION.
This task covers:
c. Follow-on Maintenance
a. Removal
b. Installation
INITIAL SETUP
References
Models
None
All
Equipment Condition
Test Equipment
None
TM or Para
Condition Description
Special Tools
TM 9-2320-279-20 Engine cover removed.
None
Special Environmental Conditions
Supplies
None
Cement, general purpose, synthetic base,
General Safety Instructions
Item 12, Appendix C
None
Personnel Required
Level of Maintenance
MOS 63W, Wheel vehicle repairer
Direct Support
a. Removal.
(1) Loosen seal ring clamp (1) and slide clamp off blower drive seal ring (2)
(2) Cut and remove blower drive seal ring (2).
b. Installation.
NOTE
Make sure cut ends of blower drive seal ring are straight and
clean.
(1) Cut blower drive seal ring (1) straight across.
WARNING
Use general purpose cement lightly and avoid contact with skin.
Cement will burn on contact.
(2) Apply general purpose cement to one end (2) of cut blower drive seal ring (1).