(2) Specific
application
to
part
No.
(b) Plug the reflectoscope into a 115 volt
10865297 cylinder (thick
wall cylinder
with
10 volt, 50 / 60 cycle single phase power
source. Turn the POWER (SCALE ILLUM)
groove in periphery of mounting flange). T h e
reflectoscope, search unit fixture, and master
knob
clockwise
and
allow
time
for
warm-up
combination provides a
checking
cylinder
(approximately
10-15
minutes).
specific functional detection method. The pulser
(c) Adjust the
sweep
delay
(upper
left
of the reflectoscope transmits short bursts, or
hand
control panel).
pulses, of electrical energy through a cable to the
(1) T u r n
the
SWEEP
DELAY
knob
search unit fixture at which point these pulses
(red) clockwise to "1".
are routed to the piezoelectric probe. The probe
(2) A d j u s t
the
SWEEP
DELAY
knob
changes
the
electrical
pulses
into
ultrasonic
(inner black) to adjust the initial pulse wave over
energy and transmits them through the trans-
the left hand vertical division marker on the
mitting medium (water) into and through the
display
screen.
cylinder barrel wall, toward the outside diameter
(3) Place the SWEEP toggle switch to
of the aluminum muff or crack, and back by the
"PRESET".
same route to the probe. The probe then changes
(4) P l a c e
the left hand INCH-
ES
/
DIV
lever
to
"2",
and,
place
the
right
the ultrasonic energy into electrical pulses which
are transmitted by cable back to the reflec-
hand lever to "1".
toscope where a characteristic wave form is
(5) T u r n t h e M A R K E R S k n o b ( r e d )
in the screen. Additionally, the
displayed
counterclockwise to "OFF".
reflectoscope embodies an alarm system which
(6) Turn theALT.
DISPLAY
SHIFT
may be set to a specific level, to signal when the
VERT
screw
fully
counterclockwise.
crack or flaw is detected in the cylinder.
(d) Pulser / receiver unit adjustment.
d. Detailer Calibration of the Cylinder Barrel
(1) P l a c e
the
TEST
switch
to
Tester.
"NORMAL".
(1) G e n e r a l . T h e f o l l o w i n g a d j u s t m e n t s
(2) T u r n
the
knob
to
apply to a new tester. Once these adjustments
"5.0".
(3) P l a c e t h e S E N S I T I V I T Y s w i t c h t o
have been made, they will seldom require
readjustment under normal conditions. Should
"X1" and turn the SENSITIVITY control knob
the inspection procedure reveal an abnormally
to "1".
high cylinder reject rate, the tester adjustments
(4) Turn the REJECT knob coun-
should be checked to be certain the readings are
terclockwise to "OFF".
correct. However, it is good practice to check all
(5) T u r n t h e P U L S E
LENGTH
knob
adjustments
periodically
to
insure
against
ac-
so that the dot is at the "12:00 o'clock" position.
cidental tampering. The reflectoscope cover and
(e) Display screen adjustment.
(1) T u r n
search fixture probe protector should be in place
the POWER (SCALE
whenever the tester is not in use.
ILLUM) knob counterclockwise, but not
Note. The cylinder barrel tester should not
"OFF".
be operated in close proximity to electrical
(2) Place
the
GATE
OFF
switch
to
appliances, or false alarming may result.
"GATE
OFF".
(2) Establish
the
wave
form
on
the
(3) Adjust the VERT screw to place
reflectoscope display screen and set the alarm.
the horizontal wave form line on the zero
(a)
Remove
the
cover
from
the
reflec-
horizontal scale line (view A, fig. 53).
toscope.
6-61
|