-4910-795-7953. The tube should be connected
b. Removal. Refer to Table 4-7 for figure
to the lower connection on the injector nozzle
references and instructions pertinent to the
tester. Close the pressure gage valve and actuate
removal of the fuel injector nozzle and holder
the pump handle rapidly (approximately 2S
assembly.
strokes per minute) to expel air from nozzle and
c. Testing.
holder and to settle spring and nozzle holding
Note. Before installing injector nozzle on
column.
nozzle tester, thoroughly clean external area to
remove carbon and dirt. Do not allow dirt to
(2) Nozzle opening pressure. Fill reservoir
with sufficient fuel to perform test. Open
enter nozzle fuel inlet opening. For nozzles that
pressure gage valve and actuate tester slowly to
do not perform properly on nozzle tester refer to
raise pressure. When nozzle opens, gage pressure
must be between 3050 psi (minimum), 3150 psi
necessary procedures `required to assure a
properly functioning nozzle and holder
(maximum). If this gage reading is not achieved,
nozzle a n d h o l d e r a s s e m b l y m u s t b e
assembly.
disassembled and spring adjusting spacers (fig.
(1) Nozzle installation. Mount the fuel
injector nozzle and holder assembly on the fuel
pressure reading.
injector nozzle tester using nozzle attaching tube
.
4-82
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |