36. REPAIRER AND HELPER TURN
RIGHT-HAND  INTERMEDIATE
HOUSING (1) OVER.
37. CHECK IWO SHOULDERED SHAFTS (2).
a. Using micrometer caliper set, measure
outside diameters of two shafts (2).
b. If either measurement is less than
0.4993 inch (12.682 mm), go to step 39.
If not, go to step 38.
38. INSPECT SCRIBE MARKS (3) ON
SHAFTS (2).
a. If scribe marks (3) are alined with small
holes in housing, go to step 40. If not,
go to step 39.
39. REPLACE RIGHT-HAND INTERMEDIATE
HOUSING. RECORD FAILURE ON DA
FORM 2407 AND RETURN DEFECTIVE
HOUSING TO DEPOT. GO TO STEP 42.
40. CLEAN RIGHT-HAND INTERMEDIATE
HOUSING.
a. Clean housing and piece parts. See
41. INSPECT RIGHT-HAND INTERMEDIATE
HOUSING.
Inspect housing, piece parts, and
a.
inserts. See page 2-5.
b. Repair inserts if damaged. See task
REPAIR RIGHT-HAND INTERMEDIATE
HOUSING INSERTS, page 4-195.