TM 9-2520-270-34
33. CHECK BEARING BORE (1).
34. CHECK BEARING BORE (2).
I
a. Using telescoping gage set and
a. Using telescoping gage set and
micrometer caliper set, measure inside
micrometer caliper set, measure inside
diameter of bore (1).
diameter of bore (2).
b. If measurement is greater than
b. If measurement is greater than 4.5290
5.9051 inches (150.000 mm), go to
inches (115.037 mm), go to step 39. If
step 39. If not, go to step 34.
not, go to step 35.
3 5 . CHECK Mechanical HOUSING (3).
a. Using micrometer caliper set, measure
outside diameter of mechanical
housing (3).
b. If measurement is less than
3.1478 inches (79.954 mm), go to
step 39. If not, go to step 36.
4-190
Change 4
|