TM 9-2520-270-34
REPLACE
LOCKRING
INSERT
DESCRIPTION
This subtask covers: Remove (Page 2-176). Install (page 2-177).
1 . COUNTERBORE LOCKRING
INSERT (1).
a. Using portable electric drill, indicator
2. REMOVE INSERT (1) WITH
caliper, and removal tool (2), drill
LOCKRING (3).
through Iockring (3) and neck of
insert (4).
a. Drive screw extractor (7) through
Iockring (3) into insert (1).
b. Drill to existing counterbore
depth (5).
b. Using screw extractor (7), unscrew
insert (1). Lockring (3) will be
c. Remove all serration interlocks (6)
forced out with insert (1).
on Iockring (3) and neck of insert (4).
WARNING
Compressed air can injure
you and others. Do not aim air
at soldiers. Do not use more
pressure than 30 psi (207 kPa).
Always wear goggles.
3. CLEAN HOUSING THREADS (8).
Lubricate thread cutting tap (9) with
a.
4.
INSPECT HOUSING THREADS (8) FOR
transmission oil.
WEAR OR STRIPPING.
b.
Using tap wrench and thread cutting
a. If housing threads (8) are damaged, go
tap (9), clean housing threads (8).
to step 5. If not, go to step (6).
Slowly turn tap in and out of housing
threads. See task for proper tap.
R E P L A C E OUTPUT HOUSING. RECORD
5.
FAILURE ON DA FORM 2407 AND
Using compressed air, blow dirt and
c.
RETURN DEFECTIVE HOUSING TO
any loose metal chips out of housing
DEPOT.
threads (8).
Change 2
2-176
|