TM 9-2520-249-34& P
32. Using puller kit (1) shield (6), and adapters (5).
31. Position torque converter housing (1) on its side as
remove pump drive gear (4) and bearing (3).
shown.
Remove diaphragm seal ring (2). Tap bearing (3)
out of drive gear (4).
CAUTION
Before moving housing, grasp the turbine
shaft refer to step 30, callout (1) above) to
prevent an downward movement housing.
An downward movement might damage the
pitot and / or vanes in the pitot oil collector.
Remove diaphragm (2) by inserting driver (3) through
the rear of the housing. Tap the driver sharply with a
hammer to unseat the diaphragm.
NOTE
Do not remove the diaphragm center oil seal
unless replacement is necessary.
33. Flatten corners of lockstrip (1). Using a 5 / 16 inch
wrench, remove two bolts 121 from the pitot tube.
The pitot tube will fall free within the collector ring.
Remove the lockstrip
6-10
|