|
|
TM 750-245-4
Table 7-5. Stranded Conductors Inspection Criteria
Inspection criteria
Illustration
ACCEPTABLE
Joint is under no tension
Original lay or twist of the wire has been main-
tained
MINIMUM ACCEPTABLE
Diameter of loop is sufficient to avoid tension on
joint
Original lay or twist of the wire has been
maintained
Insulation rough
REJECT
Wire has been bent in a sharp right angle bend
causing strands to kink
Strands have been flared on terminal
Lead not terminated at base of terminal
Not cleaned properly
7-14
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |