TM 750-245-4
shown, solder coverage should be the same regardless
7-18. Solder Coverage-Turret Terminals
of routing.
terminals.
7-20. Soldering of Components
7-19. Solder Coverage-Bifurcated Terminals
soldering for installation of components in electronic
equipment.
bifurcated terminals, only side route connections are
Table 7-4. Insulation
Inspection Criteria
Illustration
ACCEPTABLE
Insulation is unmarked
Exposed bare wire is held to a minimum
Trim is neat and even
MINIMUM ACCEPTABLE
Minor scorch marks on insulation
Trim is slightly irregular
Exposed wire is within tolerance with no sign of
wicking
REJECT
Insulation has been burned
Excess heat and solder has caused
Very bad connection - excess heat
Excess solder (lead not discernible)
Cold solder
Rosin entrapment
Lead not terminated at base of terminal
Lead extends outside of terminal
7-13
|