TM 750-245-4
Table 7-6. Cup Connectors
Inspection criteria
Illustration
ACCEPTABLE
Conductor is correct size for cup application
Solder completely fills the cup and follows the
contour of the cup entry slot
Strands visible
MINIMUM ACCEPTABLE
Conductor is maximum size for cup application
All strands are within cup and fully seated
Minimum solder; however, there is no evidence
of wicking, nor does the solder extend beyond
cup diameter
REJECT
Conductor is too big for cup application
Connection contains loose strands and have been
cut to reduce size of conductor to fit cup
Conductor not in to cup bottom
Solder is wicked and peaked
7-15