4920-00-176-9236 ">
|
|
TM 55-4920-424-13&P
SECTION IV
MAINTENANCE INSTRUCTIONS
4-1.
GENERAL.
4-2. Maintenance of the mobile check stand consists of periodic lubrication, specified in figure 4-1, and of performing the
inspection checks described in figure 4-4. Common repair procedures are not given; such repairs should be made in
accordance with standard practices. When an item is unique or sufficiently complex so as to require special instructions
and precautions, the repair procedures are given in Section VII.
4-3.
CLEANING.
4-4. Clean metal parts with cleaning solvent (item 1, App D). Wipe clean with a clean dry cloth. Parts may be sprayed
or immersed in the solvent, whichever is convenient. Apply service-approved corrosion-preventive compounds on all
steel parts after cleaning. Clean all electrical parts with a soft-bristle brush or a lint-free cloth. Remove all traces of
corrosion or other deposits that may interrupt electrical continuity.
4-5.
PERIODIC LUBRICATION.
4-6.
Perform periodic lubrication of the check stand in the manner and at the intervals prescribed in figure 4-1.
Figure &
Index No.
Item
Interval
Method
Lubricant
1, Fig. 4-2
Lube Fittings
180 Days
Grease Gun
Item 2, App D
2, Fig. 4-2
Wheel Bearings
180 Days
Hand Pack
Item 2, App D
3, Fig. 4-2
Moving Parts
180 Days
Oil Can
Item 3, App D
Speed Increaser
180 Days
Drain and Fill
Item 4, App D
Figure 4-1. Table of Periodic Lubrication